Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview AFRISOcloud AFRISOcloud Overview Monitoring containers and tanks Monitoring of separators Heat source manifold HSM Heat source manifold HSM Overview Hybrid application System possibilities Challenge AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway products Security Comfort Indoor climate Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home OEM-Manifold systems Hygienic processes Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search ... STB 67585X STB LS1 75°C 1500mm 67585X Link copied! Images 3 Back Safety temperature cut outs STB LS1/971 FU | 67585X Safety temperature cut outs STB With capillary tube in-stock items Downloads Benefits ideal for heating and process industriesfor protection against exceeding the maximum temperatureno external power supplymanual reset Application There are many application areas for safety temperature cut outs in the heating and process industries. In conventional oil-fired or gas-fired boilers, these devices are used to monitor the boiler water. The safety temperature cut outs feature a manual reset button which must be actuated for unlocking. Description If the temperature at the probe increases, the measuring liquid in the measuring system expands. If the temperature exceeds a critical value, the device triggers, the voltage-free contact switches and the system is set to a defined safe state. When the temperature has decreased by approx. 15 K, the device can be unlocked and the system resumes operation. Technical data Technical drawings Downloads Technical data TypeLS1Switching pointsee ordering tableTolerance+0 K/-6 K at 20 °CInfluence of ambient temperature 0.25 °C/°CSwitching differential∆T 15 ± 8 KFail safe1ProbeCopper∅ 6.5 x 95 mmProbe elementliquid-filledOperating temperature rangeProbe: max. 125 °CHousing: max. 85 °CCapillary tubeCu capillary tube with PVC coating, blackLength: 1500 mmDegree of protectionIP 00 (EN 60529)Time constantDIN-testedDIN EN 14597:2012-09registration number: TR/STB 1211electrical switching contactChangeover contactContact ratingNC: AC 250 V, 16 (2.5) ANO: AC 250 V, 0.5 A Technical drawings Click the corresponding image for detail views, additional information and dimension tables. STB - Gehäusemaße Siegellack Maße (mm) STB - Gehäuse- und Fühlermaße Maße (mm) Downloads Safety temperature cut outs STB LS1/971 FU 67585X datasheet variant Domestic Technology PDF English German (Germany) STB P39339 datasheet product Domestic Technology PDF English German (Germany) Related products
Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Images 3 Back Safety temperature cut outs STB LS1/971 FU | 67585X Safety temperature cut outs STB With capillary tube in-stock items Downloads Benefits ideal for heating and process industriesfor protection against exceeding the maximum temperatureno external power supplymanual reset Application There are many application areas for safety temperature cut outs in the heating and process industries. In conventional oil-fired or gas-fired boilers, these devices are used to monitor the boiler water. The safety temperature cut outs feature a manual reset button which must be actuated for unlocking. Description If the temperature at the probe increases, the measuring liquid in the measuring system expands. If the temperature exceeds a critical value, the device triggers, the voltage-free contact switches and the system is set to a defined safe state. When the temperature has decreased by approx. 15 K, the device can be unlocked and the system resumes operation. Technical data Technical drawings Downloads Technical data TypeLS1Switching pointsee ordering tableTolerance+0 K/-6 K at 20 °CInfluence of ambient temperature 0.25 °C/°CSwitching differential∆T 15 ± 8 KFail safe1ProbeCopper∅ 6.5 x 95 mmProbe elementliquid-filledOperating temperature rangeProbe: max. 125 °CHousing: max. 85 °CCapillary tubeCu capillary tube with PVC coating, blackLength: 1500 mmDegree of protectionIP 00 (EN 60529)Time constantDIN-testedDIN EN 14597:2012-09registration number: TR/STB 1211electrical switching contactChangeover contactContact ratingNC: AC 250 V, 16 (2.5) ANO: AC 250 V, 0.5 A Technical drawings Click the corresponding image for detail views, additional information and dimension tables. STB - Gehäusemaße Siegellack Maße (mm) STB - Gehäuse- und Fühlermaße Maße (mm) Downloads Safety temperature cut outs STB LS1/971 FU 67585X datasheet variant Domestic Technology PDF English German (Germany) STB P39339 datasheet product Domestic Technology PDF English German (Germany)
Safety temperature cut outs STB LS1/971 FU 67585X datasheet variant Domestic Technology PDF English German (Germany)