Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview AFRISOcloud AFRISOcloud Overview Monitoring containers and tanks Monitoring of separators Heat source manifold HSM Heat source manifold HSM Overview Hybrid application System possibilities Challenge AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway products Security Comfort Indoor climate Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home OEM-Manifold systems Hygienic processes Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search ... HY 80 63575 HY 80 0/10bar-0/100mWS 1/2 rad Kl.2,5 63575 Link copied! Images 6 Back Hydrometers HY 80 | 63575 Hydrometers HY for heating/plumbing in-stock items Manuals Technical data Technical drawings Downloads Technical data Nominal size80accuracy class (EN 837-1/6)2,5ranges0/10 barapplication areastatic load: ¾ x full scale valuedynamic load: ⅔ x full scale valueshort-term: Full scale valueOperating temperature rangeMedium: max. 60 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,4 %/10 K,falling temperature approx. ± 0.4 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 32 (EN 60529) Standard design ConnectionBrass, bottomNG 80: G½BMeasuring elementBourdon tube, "C" type tubeCopper alloymovementBrassDialKunststoff, weißdual scale bar outer - mWC innerScaling blackPointerKunststoff, schwarzHousingKunststoff (ABS), schwarz, highly impact-resistant and corrosion-resistantwindowKunststoff, eingeclipstwith adjustable red reference pointer Technical drawings Click the corresponding image for detail views, additional information and dimension tables. RF 80/HY 80/HZ 80 – bottom connection Dimensions (mm) NG a b1 c G h s SW 80 12,8 32,8 17 G½B 64 2,8 14 Downloads dials for pressure gauges – graduation technical information PDF English German (Germany) Hydrometers HY 80 63575 datasheet variant Domestic Technology PDF English German (Germany) HY 80 P25283 datasheet product Domestic Technology PDF English German (Germany) EC-Declaration of Conformity pressure gauges Declarations of Conformity PDF Download mounting of pressure gauge operating instructions Industrial technology PDF Download bourdon tube pressure gauges, capsule pressure gauges, diaphragm pressure gauges, spring diaphragm pressure gauge for differential pressure operating instructions Industrial technology PDF Ukrainian English German (Germany) Related products
Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Images 6 Back Hydrometers HY 80 | 63575 Hydrometers HY for heating/plumbing in-stock items Manuals Technical data Technical drawings Downloads Technical data Nominal size80accuracy class (EN 837-1/6)2,5ranges0/10 barapplication areastatic load: ¾ x full scale valuedynamic load: ⅔ x full scale valueshort-term: Full scale valueOperating temperature rangeMedium: max. 60 °CAmbient: -20/+60 °CTemperature performanceIndication error when the temperature of the measuring system deviates from the normal temperature of 20 °C:bei Temperaturzunahme ca. ± 0,4 %/10 K,falling temperature approx. ± 0.4 %/10 Kvom jeweiligen SkalenendwertDegree of protectionIP 32 (EN 60529) Standard design ConnectionBrass, bottomNG 80: G½BMeasuring elementBourdon tube, "C" type tubeCopper alloymovementBrassDialKunststoff, weißdual scale bar outer - mWC innerScaling blackPointerKunststoff, schwarzHousingKunststoff (ABS), schwarz, highly impact-resistant and corrosion-resistantwindowKunststoff, eingeclipstwith adjustable red reference pointer Technical drawings Click the corresponding image for detail views, additional information and dimension tables. RF 80/HY 80/HZ 80 – bottom connection Dimensions (mm) NG a b1 c G h s SW 80 12,8 32,8 17 G½B 64 2,8 14 Downloads dials for pressure gauges – graduation technical information PDF English German (Germany) Hydrometers HY 80 63575 datasheet variant Domestic Technology PDF English German (Germany) HY 80 P25283 datasheet product Domestic Technology PDF English German (Germany) EC-Declaration of Conformity pressure gauges Declarations of Conformity PDF Download mounting of pressure gauge operating instructions Industrial technology PDF Download bourdon tube pressure gauges, capsule pressure gauges, diaphragm pressure gauges, spring diaphragm pressure gauge for differential pressure operating instructions Industrial technology PDF Ukrainian English German (Germany)
bourdon tube pressure gauges, capsule pressure gauges, diaphragm pressure gauges, spring diaphragm pressure gauge for differential pressure operating instructions Industrial technology PDF Ukrainian English German (Germany)