Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview AFRISOcloud AFRISOcloud Overview Monitoring containers and tanks Monitoring of separators Heat source manifold HSM Heat source manifold HSM Overview Hybrid application System possibilities Challenge AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway products Security Comfort Indoor climate Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home OEM-Manifold systems Hygienic processes Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search ... NB 220 H 53219 Messumformer NB 220 H DC 24V 53219 Link copied! Images 3 Back Transducer NB 220 H DC 24 V | 53219 Transducer NB 220 H for overfill prevention system (WHG) in-stock items Downloads Benefits compact designeither as 230 V or as 24 V version Application To avoid overfilling of stationary tanks and stationary-use tanks. Suitable for a wide range of flammable and non-flammable water-polluting liquids with a flash point of > 55 °C (see product description UFS 01 for list of substances). Description Type-approved together with all level probes type series 76 as part of an overfill prevention system. When the level probe comes in contact with the liquid, the relay switches. Alarm units for visual and audible alarms are additionally required. Technical data Downloads Technical data Operating temperature rangeAmbient: -20/+60 °CStorage: -25/+60 °CSupply voltageDC 24 VNominal powermax. 6 WSwitching outputRelay contact: 1 x voltage-free changeover contactContact rating: max. AC 250 V, 4 A, 500 VAmax. DC 250 V, 0.25 A, 50 WHousingplug-in housingW x H x D: 50 x 110 x 110 mmDegree of protection: IP 30 (EN 60529)approvalDIBt: Z-65.11-193 Downloads NB 220 H P31200 datasheet product Domestic Technology PDF English German (Germany) Transducer NB 220 H 53219 datasheet variant Domestic Technology PDF English German (Germany) WATCHDOG-LINE alarm units brochures PDF English German (Germany) overfill prevention system NB 220 / UFS Certificates / DIBt approvals PDF Download overfill prevention system NB 220 / UFS operating instructions Domestic Technology PDF Download Related products
Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Images 3 Back Transducer NB 220 H DC 24 V | 53219 Transducer NB 220 H for overfill prevention system (WHG) in-stock items Downloads Benefits compact designeither as 230 V or as 24 V version Application To avoid overfilling of stationary tanks and stationary-use tanks. Suitable for a wide range of flammable and non-flammable water-polluting liquids with a flash point of > 55 °C (see product description UFS 01 for list of substances). Description Type-approved together with all level probes type series 76 as part of an overfill prevention system. When the level probe comes in contact with the liquid, the relay switches. Alarm units for visual and audible alarms are additionally required. Technical data Downloads Technical data Operating temperature rangeAmbient: -20/+60 °CStorage: -25/+60 °CSupply voltageDC 24 VNominal powermax. 6 WSwitching outputRelay contact: 1 x voltage-free changeover contactContact rating: max. AC 250 V, 4 A, 500 VAmax. DC 250 V, 0.25 A, 50 WHousingplug-in housingW x H x D: 50 x 110 x 110 mmDegree of protection: IP 30 (EN 60529)approvalDIBt: Z-65.11-193 Downloads NB 220 H P31200 datasheet product Domestic Technology PDF English German (Germany) Transducer NB 220 H 53219 datasheet variant Domestic Technology PDF English German (Germany) WATCHDOG-LINE alarm units brochures PDF English German (Germany) overfill prevention system NB 220 / UFS Certificates / DIBt approvals PDF Download overfill prevention system NB 220 / UFS operating instructions Domestic Technology PDF Download