Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview AFRISOcloud AFRISOcloud Overview Monitoring containers and tanks Monitoring of separators Heat source manifold HSM Heat source manifold HSM Overview Hybrid application System possibilities Challenge AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway products Security Comfort Indoor climate Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home OEM-Manifold systems Hygienic processes Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search ... PrimoTherm® 180-3 DN25 RTA 77576 PrimoTherm 180-3 DN25 RTA60 OP G1ixG1i 77576 Link copied! Images 1 Back Heating pump assembly PrimoTherm® 180-3 DN 25 RTA 60 | 77576 Heating pump assembly PrimoTherm® 180-3 DN 25 RTA in-stock items Manuals Benefits for increased return temperature with solid fuel boilerswith temperature-controlled condensation protection valvefor reduced amounts of condensate in the combustion processavoids deposits in the boiler and in the smoke venteligible for heating optimization program (BAFA) Application Heating pump assembly for automatically controlling the return temperature of the system water to the heat generator to the value adjusted in the valve. An integrated, temperature-controlled condensation protection valve is the connection between the solid fuel heating system and the heating circuit or the hot water storage tank. Using PrimoTherm® 180-3 RTA keeps the temperature in the heating boiler above the condensation point in all operating states. This avoids deposits in the boiler and in the smoke vent and increases the service life of the system; corrosion damage of the heating boiler and chimney fires caused by soot deposits are avoided. Description Complete, pre-assembled and tightness-tested heating pump assembly with all required functional components, form-fit insulation and wall mounting unit. With an additional mounting bracket, the unit can be mounted in any position (vertically/horizontally).The return line consists of:Combination valve with thermometer in the hand wheel (blue mark, range 0/120 °C)Ball valve above the pump3-way mixing valve with fixed mixing temperature 60 °CSystem connection G1 female (boiler), G1 female (storage)Suitable for pumps DN 25 with G1½ x 180 mm.The flow line (hot) consists of:Combination valve with gravity brake, thermometer in the handle (red mark, range 0/120 °C)Pipe for length compensation with screw connectionSystem connection G1 female (boiler), G1 female (storage) Technical data Downloads Technical data Axis distance 125 mmsystem connectionsBoiler: G1 femaleHeating circuit: G1 femaleOperating temperature rangeMedium: max. 100 °CSystem pressuremax. 10 barNominal sizeDN 25System capacitymax. 32 kW max. at a flow rate of 1,400 I/h and a temperature spread of ∆t 20 KLeak ratewater-tight between connections A->ABHeat insulationPolypropylene EPPDimensionsW x H x D: 250 x 475 x 153 mmOptionsother opening temperaturesandere Umwälzpumpen Downloads Heating pump assembly PrimoTherm® 180-3 DN25 RTA P31025 datasheet product Domestic Technology PDF English German (Germany) Heating pump assembly PrimoTherm® 180-3 DN 25 RTA 60 77576 datasheet variant Domestic Technology PDF English German (Germany) system assemblies for domestic technology brochures PDF English German (Germany) Heating pump assembly PrimoTherm® K 180-1 DN 25, K 180-2 DN 25 operating instructions PDF Download Related products
Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Images 1 Back Heating pump assembly PrimoTherm® 180-3 DN 25 RTA 60 | 77576 Heating pump assembly PrimoTherm® 180-3 DN 25 RTA in-stock items Manuals Benefits for increased return temperature with solid fuel boilerswith temperature-controlled condensation protection valvefor reduced amounts of condensate in the combustion processavoids deposits in the boiler and in the smoke venteligible for heating optimization program (BAFA) Application Heating pump assembly for automatically controlling the return temperature of the system water to the heat generator to the value adjusted in the valve. An integrated, temperature-controlled condensation protection valve is the connection between the solid fuel heating system and the heating circuit or the hot water storage tank. Using PrimoTherm® 180-3 RTA keeps the temperature in the heating boiler above the condensation point in all operating states. This avoids deposits in the boiler and in the smoke vent and increases the service life of the system; corrosion damage of the heating boiler and chimney fires caused by soot deposits are avoided. Description Complete, pre-assembled and tightness-tested heating pump assembly with all required functional components, form-fit insulation and wall mounting unit. With an additional mounting bracket, the unit can be mounted in any position (vertically/horizontally).The return line consists of:Combination valve with thermometer in the hand wheel (blue mark, range 0/120 °C)Ball valve above the pump3-way mixing valve with fixed mixing temperature 60 °CSystem connection G1 female (boiler), G1 female (storage)Suitable for pumps DN 25 with G1½ x 180 mm.The flow line (hot) consists of:Combination valve with gravity brake, thermometer in the handle (red mark, range 0/120 °C)Pipe for length compensation with screw connectionSystem connection G1 female (boiler), G1 female (storage) Technical data Downloads Technical data Axis distance 125 mmsystem connectionsBoiler: G1 femaleHeating circuit: G1 femaleOperating temperature rangeMedium: max. 100 °CSystem pressuremax. 10 barNominal sizeDN 25System capacitymax. 32 kW max. at a flow rate of 1,400 I/h and a temperature spread of ∆t 20 KLeak ratewater-tight between connections A->ABHeat insulationPolypropylene EPPDimensionsW x H x D: 250 x 475 x 153 mmOptionsother opening temperaturesandere Umwälzpumpen Downloads Heating pump assembly PrimoTherm® 180-3 DN25 RTA P31025 datasheet product Domestic Technology PDF English German (Germany) Heating pump assembly PrimoTherm® 180-3 DN 25 RTA 60 77576 datasheet variant Domestic Technology PDF English German (Germany) system assemblies for domestic technology brochures PDF English German (Germany) Heating pump assembly PrimoTherm® K 180-1 DN 25, K 180-2 DN 25 operating instructions PDF Download
Heating pump assembly PrimoTherm® 180-3 DN25 RTA P31025 datasheet product Domestic Technology PDF English German (Germany)
Heating pump assembly PrimoTherm® 180-3 DN 25 RTA 60 77576 datasheet variant Domestic Technology PDF English German (Germany)