Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview AFRISOcloud AFRISOcloud Overview Monitoring containers and tanks Monitoring of separators AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway products Security Comfort Indoor climate Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home Heat source manifold HSM Heat source manifold HSM Overview Hybrid application System possibilities Challenge Refrigerant circuit OEM-Manifold systems Hygienic processes Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search Domestic technology Equipment for heating systems, boiler rooms and chimneys Frost protection valve AAV Link copied! This product is not available in your country Images 2 Frost protection valve AAV Frost protection valve for heat pumps Variants Downloads Benefits for protecting monobloc or hydrosplit heat pumps against frost damage in the case of malfunctions or power outagehelps to avoid major damage to system componentswith integrated vacuum breakerintegrated mounting valve for easy replacement of the thermostatic elementmaintenance-free Application For applications with monobloc or hydrosplit heat pumps that are connected directly to the heating circuit water outdoors. Description A frost protection valve with integrated vacuum breaker is installed in the flow and return lines of the system. The valve must be installed as close as possible to the outdoor unit of the heat pump so that sensitive components of the heat pump are protected from damage caused by freezing of the heating circuit water. If maintenance is required, the thermostatic cartridge can be replaced, checked and reinstalled without draining the heating circuit water thanks to the integrated mounting valve. Additional information Technical data Downloads Additional information If the temperature of the medium in the heating system drops to 3 °C, the thermostatic element inside the valve opens so the medium can flow to the outside. The resulting negative pressure opens the vacuum breaker and supports the draining of components such as the heat exchanger, pipes, pumps or valves. If the temperature of the medium rises above 4 °C, the thermostatic element automatically shuts off the flow of the medium from the system. Technical data System connectionAAV 103: G1 maleAAV 303: G1¼ AGFlow coefficient KvsAAV 103: 55 m³/hAAV 303: 70 m³/hNominal pressuremax. 10 barOpening temperature (medium)3 °C (± 1 °C)Closing temperature (medium)4 °C (± 1 °C)Operating temperature rangeMedium: 0/90 °CAmbient: -30/+60 °CMaterialHousing: brass (CW617N)spring: Stainless steelseals: EPDM Downloads Frost protection valve AAV 102, 302 Mounting instructions PDF Download Related products
Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
This product is not available in your country Images 2 Frost protection valve AAV Frost protection valve for heat pumps Variants Downloads Benefits for protecting monobloc or hydrosplit heat pumps against frost damage in the case of malfunctions or power outagehelps to avoid major damage to system componentswith integrated vacuum breakerintegrated mounting valve for easy replacement of the thermostatic elementmaintenance-free Application For applications with monobloc or hydrosplit heat pumps that are connected directly to the heating circuit water outdoors. Description A frost protection valve with integrated vacuum breaker is installed in the flow and return lines of the system. The valve must be installed as close as possible to the outdoor unit of the heat pump so that sensitive components of the heat pump are protected from damage caused by freezing of the heating circuit water. If maintenance is required, the thermostatic cartridge can be replaced, checked and reinstalled without draining the heating circuit water thanks to the integrated mounting valve. Additional information Technical data Downloads Additional information If the temperature of the medium in the heating system drops to 3 °C, the thermostatic element inside the valve opens so the medium can flow to the outside. The resulting negative pressure opens the vacuum breaker and supports the draining of components such as the heat exchanger, pipes, pumps or valves. If the temperature of the medium rises above 4 °C, the thermostatic element automatically shuts off the flow of the medium from the system. Technical data System connectionAAV 103: G1 maleAAV 303: G1¼ AGFlow coefficient KvsAAV 103: 55 m³/hAAV 303: 70 m³/hNominal pressuremax. 10 barOpening temperature (medium)3 °C (± 1 °C)Closing temperature (medium)4 °C (± 1 °C)Operating temperature rangeMedium: 0/90 °CAmbient: -30/+60 °CMaterialHousing: brass (CW617N)spring: Stainless steelseals: EPDM Downloads Frost protection valve AAV 102, 302 Mounting instructions PDF Download