Products Our motto "Technology for Environmental Protection" has long been an inherent part of our product development philosophy and product range. More Informations Industries & Topics Industries & Topics Overview AFRISOcloud AFRISOcloud Overview Monitoring containers and tanks Monitoring of separators Heat source manifold HSM Heat source manifold HSM Overview Hybrid application System possibilities Challenge AFRISO Smart Home AFRISO Smart Home Overview Gateway HG 02 Products Products Overview Gateway products Security Comfort Indoor climate Alexa Smart home applications Smart home applications Overview Leakage security Security Stand-alone applications Stand-alone applications Overview Getting started with AFRIShome Smart Home OEM-Manifold systems Hygienic processes Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search ... DFM 15-2M 80961 DFM 15-2M G1 x G1 ÜM 1–6 l/min 80961 Link copied! Images 1 Back Flow meter DFM 15-2M | 80961 Flow meter DFM 15-2M manufactured goods Manuals Benefits integrated ball valve for adjustment and shutting offdirect indication of the flow rate in l/minadjustment without diagram, table or measuring instrumentavailable with many connection types Application For hydraulic balancing and flow monitoring in heating/cooling systems, air conditioning systems, solar systems and geothermal systems. DFM allows for fast hydraulic balancing of the system or of system components without diagrams, tables or measuring instruments. Suitable for heating and cooling water as well as water mixtures with standard corrosion protection and antifreeze agents. Description Compact flow meter with scale and ball valve for shutting off and adjustment. The flow meter can be installed in pipes in a horizontal, tilted or vertical position. Adjustments are made by means of a screwdriver via the adjustment screw. The reading mark corresponds to the lower edge of the rotameter/float. Systems with correct hydraulic balancing provide for optimum energy distribution and cost-efficient operation. Technical data Technical drawings Downloads Technical data Operating temperature rangemax. 120 °C, short-term 160 °COperating pressuremax. 10 barMeasuring principleRotameter type with counter spring1/6 l/minNominal diameterDN 15HousingBrass, nickel-platedConnectionG1 male x G1 union nutMounting positionhorizontal, tilted or verticalOptionsother nominal diametersandere Anschlüsseother measuring ranges Technical drawings Click the corresponding image for detail views, additional information and dimension tables. DFM 15-2M, Außengewinde x Überwurfmutter Maße (mm) Downloads Flow meter DFM 15-2M 80961 datasheet variant Domestic Technology PDF English German (Germany) Flow meter DFM 15-2M P7166 datasheet product Domestic Technology PDF English German (Germany) flow meters DFM operating instructions PDF Download Related products
Hygienic processes Sterile process separation, hygienic design, material quality – adapted to suit specific industrial production processes, AFRISO products meet the most demanding requirements and hygiene regulations. More Informations Service-Center Service-Center Overview Service Contact persons Catalogues Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Service-Center Flexible, cost-aware, on schedule, solution-oriented and fast – the AFRISO team always provides the decisive added value. More Informations Exhibitions Search
Images 1 Back Flow meter DFM 15-2M | 80961 Flow meter DFM 15-2M manufactured goods Manuals Benefits integrated ball valve for adjustment and shutting offdirect indication of the flow rate in l/minadjustment without diagram, table or measuring instrumentavailable with many connection types Application For hydraulic balancing and flow monitoring in heating/cooling systems, air conditioning systems, solar systems and geothermal systems. DFM allows for fast hydraulic balancing of the system or of system components without diagrams, tables or measuring instruments. Suitable for heating and cooling water as well as water mixtures with standard corrosion protection and antifreeze agents. Description Compact flow meter with scale and ball valve for shutting off and adjustment. The flow meter can be installed in pipes in a horizontal, tilted or vertical position. Adjustments are made by means of a screwdriver via the adjustment screw. The reading mark corresponds to the lower edge of the rotameter/float. Systems with correct hydraulic balancing provide for optimum energy distribution and cost-efficient operation. Technical data Technical drawings Downloads Technical data Operating temperature rangemax. 120 °C, short-term 160 °COperating pressuremax. 10 barMeasuring principleRotameter type with counter spring1/6 l/minNominal diameterDN 15HousingBrass, nickel-platedConnectionG1 male x G1 union nutMounting positionhorizontal, tilted or verticalOptionsother nominal diametersandere Anschlüsseother measuring ranges Technical drawings Click the corresponding image for detail views, additional information and dimension tables. DFM 15-2M, Außengewinde x Überwurfmutter Maße (mm) Downloads Flow meter DFM 15-2M 80961 datasheet variant Domestic Technology PDF English German (Germany) Flow meter DFM 15-2M P7166 datasheet product Domestic Technology PDF English German (Germany) flow meters DFM operating instructions PDF Download